Açıklama
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are paramount.
Technology
Patented BACross III fill pack system allows simple inspection of the fill sheets to prevent biological growth (e.g. Legionella).
Key Features of the S1500E Series
- Maintenance Access: Large, inward-swinging access door and internal maintenance platforms enable technicians to perform inspections comfortably while standing inside the unit.
- Hygiene Control: The design minimizes stagnant water and protects against sunlight using special air intake components, reducing algae growth.
- Flexibility: The single-side air intake allows the tower to be installed in confined spaces or directly against walls.
- Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- Air Conditioning (HVAC): Integrated in large building complexes as part of central cooling systems.
- Refrigeration Technology: Used as a condenser in commercial refrigeration circuits.
Cooling Performance
An open evaporative cooling tower does not have a fixed kW rating, as the actual capacity depends entirely on thermodynamic ambient conditions and system temperatures.
This model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
- Wet bulb temperature (ambient air): The cooler and drier the air, the more water can evaporate and the greater the cooling effect.
- Water temperatures: The performance changes significantly depending on the entering hot water temperature (e.g., 35°C) and the exiting cold water temperature (e.g., 29°C).
- Airflow volume: The S15E 1018-10 LE model, according to BAC's technical data, actively moves 60.0 m³/s of air using three 11.0 kW fan motors.
- If the airflow is reduced via frequency inverter (e.g., during night operation or in winter), the cooling capacity is deliberately reduced.
- Approach: This is the main thermodynamic limit. It describes the difference between the desired cold water temperature and the physical wet bulb temperature. The closer the cold water is cooled to the wet bulb temperature (smaller approach), the lower the tower's cooling capacity in kW.
Technical Data:
Fan & Air Data
- Airflow: 60.0 m³/s (induced draft)
- Fan Motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
Hjdjynkbmepfx Ap Henr
- Water flow: 198 l/s
Hydraulic Connections
- Water Inlet: 1x DN 250 (nominal diameter 250 mm)
- Water Outlet: 1x DN 300 (nominal diameter 300 mm)
- Make-up Water Connection: 1x DN 40 (ND 40 mm)
- Overflow/Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are paramount.
Technology
Patented BACross III fill pack system allows simple inspection of the fill sheets to prevent biological growth (e.g. Legionella).
Key Features of the S1500E Series
- Maintenance Access: Large, inward-swinging access door and internal maintenance platforms enable technicians to perform inspections comfortably while standing inside the unit.
- Hygiene Control: The design minimizes stagnant water and protects against sunlight using special air intake components, reducing algae growth.
- Flexibility: The single-side air intake allows the tower to be installed in confined spaces or directly against walls.
- Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- Air Conditioning (HVAC): Integrated in large building complexes as part of central cooling systems.
- Refrigeration Technology: Used as a condenser in commercial refrigeration circuits.
Cooling Performance
An open evaporative cooling tower does not have a fixed kW rating, as the actual capacity depends entirely on thermodynamic ambient conditions and system temperatures.
This model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model ranges from approximately 1,200 kW to 2,100 kW.
Why does cooling capacity vary?
- Wet bulb temperature (ambient air): The cooler and drier the air, the more water can evaporate and the greater the cooling effect.
- Water temperatures: The performance changes significantly depending on the entering hot water temperature (e.g., 35°C) and the exiting cold water temperature (e.g., 29°C).
- Airflow volume: The S15E 1018-10 LE model, according to BAC's technical data, actively moves 60.0 m³/s of air using three 11.0 kW fan motors.
- If the airflow is reduced via frequency inverter (e.g., during night operation or in winter), the cooling capacity is deliberately reduced.
- Approach: This is the main thermodynamic limit. It describes the difference between the desired cold water temperature and the physical wet bulb temperature. The closer the cold water is cooled to the wet bulb temperature (smaller approach), the lower the tower's cooling capacity in kW.
Technical Data:
Fan & Air Data
- Airflow: 60.0 m³/s (induced draft)
- Fan Motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
Hjdjynkbmepfx Ap Henr
- Water flow: 198 l/s
Hydraulic Connections
- Water Inlet: 1x DN 250 (nominal diameter 250 mm)
- Water Outlet: 1x DN 300 (nominal diameter 300 mm)
- Make-up Water Connection: 1x DN 40 (ND 40 mm)
- Overflow/Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
En son çevrimiçi : geçen hafta
Kayıtlı seit: 2008
588 çevrimiçi ilan
İstek gönder
Telefon & Faks
+49 2862 ... ilanlar
Bu ilanlar da ilginizi çekebilir.
Küçük ilan
Kraków
1.726 km
Soğutucu sistem
COPELANDD6DT5-320X-AWM/D (x4)
COPELANDD6DT5-320X-AWM/D (x4)
Küçük ilan
Olching
2.173 km
Dikey işleme merkezi
CHIRONFZ 08 S five axis
CHIRONFZ 08 S five axis
Küçük ilan
Łęczna
1.679 km
Soğutucu/ısı pompası
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
Küçük ilan
Niedźwiedź
1.686 km
Kompresör ünitesi
BITZER4NCS-12.2Y-40-40P (x4)
BITZER4NCS-12.2Y-40-40P (x4)
Küçük ilan
Olching
2.173 km
Dikey işleme merkezi
CHIRONFZ 08 S five axis + VarioCell -Refit-
CHIRONFZ 08 S five axis + VarioCell -Refit-
Küçük ilan
Niedźwiedź
1.686 km
Soğutma kompresörü
DWM CopelandD6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
Küçük ilan
Niedźwiedź
1.686 km
Kondenser
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Küçük ilan
Remseck am Neckar
2.341 km
Endüstriyel soğutma merkezi sistemi Bitzer ile
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Küçük ilan
Romanya
2.465 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Küçük ilan
Hillegom
2.780 km
Kuru soğutucu
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
İlanınız başarıyla silindi
Bir hata oluştu