Diferansiyel taramalı kalorimetrePerkin Elmer
DSC 8000, N5340524
Diferansiyel taramalı kalorimetre
Perkin Elmer
DSC 8000, N5340524
EXW Sabit fiyat KDV hariç
€29.750
Durum
İkinci el
Konum
Dresden 

Makineye ait bilgiler
- Makine adı:
- Diferansiyel taramalı kalorimetre
- Üretici:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Durum:
- ikinci el
Fiyat ve Konum
EXW Sabit fiyat KDV hariç
€29.750
- Konum:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Ara
Teklif detayları
- İlan Kimliği:
- A21283042
- Referans numarası:
- LW43630
- Son güncelleme tarihi:
- 20.02.2026
Açıklama
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Ijdpfx Ajyluicjkzoif
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum temperature (Intracooler 2): approx. –80 °C
Heating rate: 0.01 to 300 °C/min
Cooling rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic range: ±800 mW (typical)
High sensitivity and fast response time thanks to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: Nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet fittings
Cooling unit connection
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Coolant: 350 g R-404A
Note regarding item condition:
Sold without software/PC.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Ijdpfx Ajyluicjkzoif
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum temperature (Intracooler 2): approx. –80 °C
Heating rate: 0.01 to 300 °C/min
Cooling rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic range: ±800 mW (typical)
High sensitivity and fast response time thanks to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: Nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet fittings
Cooling unit connection
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Coolant: 350 g R-404A
Note regarding item condition:
Sold without software/PC.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
Kayıtlı seit: 2014
93 çevrimiçi ilan
İstek gönder
Telefon & Faks
+49 351 8... ilanlar
Bu ilanlar da ilginizi çekebilir.
Küçük ilan
Borken
2.615 km
Universal test kabini +20 °C ila +300 °C
MemmertUF 450plus
MemmertUF 450plus
Küçük ilan
Wald
2.317 km
Kurutma dolabı inkübatör ısıtma dolabı
BinderED 240/E2
BinderED 240/E2
Küçük ilan
İspanya
2.465 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
İlanınız başarıyla silindi
Bir hata oluştu