Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss Climate Test Chamber ClimeEvent, water-cooled
Chamber volume: 800 litres
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load: designed for a maximum payload of 250 kg
Performance data for temperature tests:
Temperature range: -55 to +180°C
Temperature fluctuation over time at the chamber centre: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating: 25 K/min
Cooling: 25 K/min (down to -45°C)
Heat compensation: max. 8000 W
Performance data for climate tests:
Dedpfx Afjw R Rt Io Deku
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Climate performance data (excerpt):
Humidity range: 10 to 98% relative humidity (r.h.)
Humidity deviation (over time): at the chamber centre, in equilibrium, dependent on set value: ±1 to ±3% r.h.
Temperature deviation (over time): at the chamber centre, in equilibrium, dependent on set value: ±0.1 to ±0.3 K
Temperature uniformity (spatial): relative to the setpoint (>20% r.h.): ±0.5 to ±1 K
Operating data:
LED bar 24 V, 6.8 W / 2 x halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ±10% 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
The chamber is equipped with a Greenmode function.
Weight: approx. 2050 kg
Important information for you as the buyer, for your safety!
The following steps are carried out in advance on all our listed chambers:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see images)
(Technical details subject to change and errors excepted!)
Please feel free to contact us by phone for any further questions.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss Climate Test Chamber ClimeEvent, water-cooled
Chamber volume: 800 litres
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load: designed for a maximum payload of 250 kg
Performance data for temperature tests:
Temperature range: -55 to +180°C
Temperature fluctuation over time at the chamber centre: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating: 25 K/min
Cooling: 25 K/min (down to -45°C)
Heat compensation: max. 8000 W
Performance data for climate tests:
Dedpfx Afjw R Rt Io Deku
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Climate performance data (excerpt):
Humidity range: 10 to 98% relative humidity (r.h.)
Humidity deviation (over time): at the chamber centre, in equilibrium, dependent on set value: ±1 to ±3% r.h.
Temperature deviation (over time): at the chamber centre, in equilibrium, dependent on set value: ±0.1 to ±0.3 K
Temperature uniformity (spatial): relative to the setpoint (>20% r.h.): ±0.5 to ±1 K
Operating data:
LED bar 24 V, 6.8 W / 2 x halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ±10% 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
The chamber is equipped with a Greenmode function.
Weight: approx. 2050 kg
Important information for you as the buyer, for your safety!
The following steps are carried out in advance on all our listed chambers:
1. Function check and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see images)
(Technical details subject to change and errors excepted!)
Please feel free to contact us by phone for any further questions.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
İstek gönder
Telefon & Faks
+49 2861 ... ilanlar
İlanınız başarıyla silindi
Bir hata oluştu