Sıcaklık test odası 600 litreWeiss
WT3-600/40 -42°C bis +180°C
Sıcaklık test odası 600 litre
Weiss
WT3-600/40 -42°C bis +180°C
Durumu
Kullanılmış
Konum
Borken 

Resimleri göster
Haritayı göster
Makineye ait bilgiler
Fiyat ve Konum
- Konum:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ara
Teklif detayları
- Listeleme kimliği:
- A21151962
- Referans no.:
- 23955
- Son güncelleme tarihi:
- 03.02.2026
Açıklama
Here we offer a Weiss temperature chamber.
Weiss Temperature Test Chamber with S!MCON / 32-Controller, Water-cooled
Control Panel: Touch Panel
All control and operating commands can be executed by simply touching the function symbols on the touch panel.
Adjustable Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Bsdpfsyguh Ijx Abrecu
Feedthroughs
The chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test equipment to be routed into the test space.
Standard feedthroughs installed:
R1: Nominal width 125 mm
L1: Nominal width 50 mm
Refrigerant converted to R-452A
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Data for temperature testing:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max.: 2500 W
Operating data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 15 A
Nominal power: 7.8 kW
Site fuse: 16 A slow-blow
Sound pressure level:
Measured at 1 m distance, from the front, at 1 m height: 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
Important safety note for you as a buyer!
The following steps are performed on all chambers we offer in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: see photo
(Technical data and specifications are subject to change and error!)
Please feel free to contact us by phone if you have any further questions.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Weiss Temperature Test Chamber with S!MCON / 32-Controller, Water-cooled
Control Panel: Touch Panel
All control and operating commands can be executed by simply touching the function symbols on the touch panel.
Adjustable Feet
To compensate for uneven floors and ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Bsdpfsyguh Ijx Abrecu
Feedthroughs
The chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test equipment to be routed into the test space.
Standard feedthroughs installed:
R1: Nominal width 125 mm
L1: Nominal width 50 mm
Refrigerant converted to R-452A
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Data for temperature testing:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max.: 2500 W
Operating data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 15 A
Nominal power: 7.8 kW
Site fuse: 16 A slow-blow
Sound pressure level:
Measured at 1 m distance, from the front, at 1 m height: 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
Important safety note for you as a buyer!
The following steps are performed on all chambers we offer in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: see photo
(Technical data and specifications are subject to change and error!)
Please feel free to contact us by phone if you have any further questions.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
İlk kayıt tarihi: 2012
İstek gönder
Telefon & Faks
+49 2861 ... ilanlar
Bu ilanlar da ilginizi çekebilir.
Küçük ilan
Borken
2.615 km
Sıcaklık test odası 600 litre
WeissWT3-600/40 -42°C bis +180°C
WeissWT3-600/40 -42°C bis +180°C
İlanınız başarıyla silindi