Nemli iklim test odasıWeiss
WK3-340/70 -70°C bis +180°C
Nemli iklim test odası
Weiss
WK3-340/70 -70°C bis +180°C
Durumu
Kullanılmış
Konum
Borken 

Resimleri göster
Haritayı göster
Makineye ait bilgiler
Fiyat ve Konum
- Konum:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ara
Teklif detayları
- Listeleme kimliği:
- A20256675
- Referans no.:
- 24818
- Son güncelleme tarihi:
- 10.10.2025
Açıklama
Type: WK3-340/70
Weiss Climate Test Chamber, Water-Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function icons on the "Touch Panel" control unit.
Ljdpfoxmg Sdjx Ac Asrw
Leveling Feet
To compensate for uneven floors and to provide adequate ventilation for the machine section, the test chamber is equipped with adjustable leveling feet.
Feedthroughs
The test chamber is fitted with feedthroughs on both the right and left sides. These allow measurement cables and testing devices to be routed into the test space.
Standard Feedthroughs Installed:
R1: NW 125 mm
L1: NW 85 mm
Volume: 335 liters
Test Space Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Testing:
Minimum Temperature: –72°C
Maximum Temperature: +180°C
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.5 K
Temperature Change Rate (Cooling): 3 K/min
Temperature Change Rate (Heating): 3 K/min
Specifications for Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1 K
Temporal Humidity Deviation: ±1 to ±3% r.h.
Operational Data:
Test Chamber Lighting: Halogen lamp, 2 x 24V, 50W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Current: 16 A
Rated Power: 4.9 kW
External Fuse: 16 A slow-blow
Refrigerant: R-452A / R23
Weight: approx. 585 kg
For your safety as a buyer, please note the following information!
The following steps are performed in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
Further questions can be answered by phone at your convenience.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Weiss Climate Test Chamber, Water-Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the function icons on the "Touch Panel" control unit.
Ljdpfoxmg Sdjx Ac Asrw
Leveling Feet
To compensate for uneven floors and to provide adequate ventilation for the machine section, the test chamber is equipped with adjustable leveling feet.
Feedthroughs
The test chamber is fitted with feedthroughs on both the right and left sides. These allow measurement cables and testing devices to be routed into the test space.
Standard Feedthroughs Installed:
R1: NW 125 mm
L1: NW 85 mm
Volume: 335 liters
Test Space Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Testing:
Minimum Temperature: –72°C
Maximum Temperature: +180°C
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.5 K
Temperature Change Rate (Cooling): 3 K/min
Temperature Change Rate (Heating): 3 K/min
Specifications for Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1 K
Temporal Humidity Deviation: ±1 to ±3% r.h.
Operational Data:
Test Chamber Lighting: Halogen lamp, 2 x 24V, 50W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Current: 16 A
Rated Power: 4.9 kW
External Fuse: 16 A slow-blow
Refrigerant: R-452A / R23
Weight: approx. 585 kg
For your safety as a buyer, please note the following information!
The following steps are performed in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
Further questions can be answered by phone at your convenience.
Bu ilan otomatik olarak tercüme edildiğinden bazı çeviri hataları oluşmuş olabilir.
Tedarikçi
Not: Ücretsiz kaydolun veya giriş yapın, tüm bilgilere erişmek için.
İlk kayıt tarihi: 2012
İstek gönder
Telefon & Faks
+49 2861 ... ilanlar
Bu ilanlar da ilginizi çekebilir.
küçük ilan
Lauchheim
5.630 km
İşleme merkezi 5 eksen
DMG MORIDMU 75 monoBLOCK
DMG MORIDMU 75 monoBLOCK
küçük ilan
Österreich
1.921 km
Hareketli sütun freze makinesi
SHWUS5-T
SHWUS5-T
küçük ilan
Nördlingen
2.253 km
Üniversal işleme merkezi
Deckel MahoDMU 80 eVo PW FD
Deckel MahoDMU 80 eVo PW FD
küçük ilan
Oelde
2.530 km
Diğerleri
Werkzeug- / Tool Package 172x SK 40
Werkzeug- / Tool Package 172x SK 40
küçük ilan
Wilbertoord
2.678 km
İşleme merkezi - dikey
DMGDMU 40 Mono Block
DMGDMU 40 Mono Block
küçük ilan
Borken
2.615 km
İklim test kabini 800 L, -55°C ile +180°C arası
WeissClimeEvent C/800/55a/25/S 25K/min
WeissClimeEvent C/800/55a/25/S 25K/min
küçük ilan
Borken
2.615 km
1000 litrelik sıcaklık test odası
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
küçük ilan
Borken
2.615 km
Nemli 335 litre iklim test odası
VötschVC 4034 -40°C..+180°C
VötschVC 4034 -40°C..+180°C
küçük ilan
Langenfeld (Rheinland)
2.580 km
Nemli iklim test odası
WeissWKL 34/40
WeissWKL 34/40
küçük ilan
Amstetten
1.927 km
Weiss iklim test kabini SB11/300/40 -40..
WEISSSB11/300/40
WEISSSB11/300/40
İlanınız başarıyla silindi
Bir hata oluştu